Practices for every control method
Record 3 or more control points per station
Three control points, not in a straight line, is the minimum to station. Record more when you can. Each extra point reduces the effect any single bad point has on the layout.
Spread points around the print area
Record points around the perimeter of the area you plan to print, not clustered inside it or on one side. Choose points that are far apart. A far point with a slightly higher error often performs better than a close point with a lower error, especially over a large print area. See How to Select Control Points for Better Stationing Accuracy.
Inspect each point before you record it
- Clean the mark. Clear dust, mud, and debris.
- Confirm the mark hasn't been scratched, covered, or ground off.
- Confirm no equipment or activity has moved or damaged the point since it was set.
Seat the reflector exactly on the point
The laser tracker records the position of the reflector, not the mark. If the reflector sits off the point, the tracker records the wrong coordinate. Never slide the reflector off the mark to make an error value drop. See Why You Shouldn't Move the Reflector to Lower Distance or Station Errors.
Keep the laser tracker stable
- Set the tripod tight and level. See How to Level the Tripod for Accurate Printing.
- Avoid vibration from nearby equipment.
Surveyed control points on the floor
This is the most common control method: a surveyor marks control points on the slab and delivers their coordinates, usually as a CSV file.
A good surveyed floor point has:
- A crisp "X" or target mark. Thick cross marks make it hard to place the reflector the same way twice.
- A legible label that matches the point name in the control list.
- A stable surface at least 3" across, away from slab cracks, spalls, and unfinished areas.
When you record:
- Clear dust, mud, and debris off the mark.
- Confirm the label on the slab matches the control point name in the Dusty App.
- Center the control point target on the mark and seat the reflector in it. See How to Use the Control Point Target to Place the Reflector on a Control Point.
If several points show high errors, ask the surveyor to verify them. Points set with a bi-pod can be off by 1/8" to 3/4" depending on technique.
Drift nests on walls and columns
Permanently mounted drift nests are one of the most accurate forms of control and give the strongest consistency from one station to the next.
A good drift nest is:
- Mounted on a stable, permanent surface, such as a concrete wall or structural column.
- Rigidly attached, not loose or spinning.
- Clean, so the reflector seats flush and stable.
When you record:
- Confirm the offset was applied to the control point coordinates. The tracker measures to the center of the reflector, not to the mark on the wall. With Dusty's vertical control point target the offset is 1-1/4". See How to Use Vertical Control Points.
- Seat the reflector carefully. Don't wiggle or bump the nest.
- Check whether construction activity may have hit or vibrated the mount since it was installed.
- Record more than the minimum when you can. More points is better.
Surveyed offset lines (grid offsets)
Some surveyors mark control at a set distance from grid lines and send the offset distances instead of a CSV file. This is common on legacy projects where contractors use axis lines snapped from a Robotic Total Station (RTS).
You are working with offset-line control when you see chalked grid lines on the slab, crossing lines that form intersection points, and no surveyed-point CSV.
When you record:
- Compare each point with the surveyor's drawing: the right two grid lines, the right distances, and the right side of each line.
- Create each control point in the Dusty App with Create Control at Intersection. See How to Create a Control Point From Any Two Non-Parallel Lines.
- Re-snap lines that are faint or disturbed.
- Avoid intersections near slab edges or curled concrete.
A line snapped in the wrong place or an offset measured wrong shows up as a high error. One point with a much larger Distance Error than the others usually means it was built from the wrong grid line, the wrong side, or the wrong distance.
Manual offsets from columns, gridlines, and slab corners
Use manual offsets only when no surveyed control is available. Surveyed control is always preferred.
Examples of manual offset references:
- Offsets from column centerlines
- Offsets from stair openings or slab corners
- Tape-measured grids
When you record:
- Check that your references are square with a 3-4-5 or diagonal check. Offsets from columns or slab edges that are not at true right angles are a common cause of high errors.
- Mark each point clearly on the slab, write its name next to it, and create it in the Dusty App.
- Record more than the minimum number of points. Manual control carries a higher risk of error.
- Have a second person check each measurement before you rely on it.
Corner control jigs
Corner control lets you station off 90° corners that already exist on site, inside or outside. A corner control jig holds the reflector 2" from each wall, and the Dusty App creates the matching control point from the two lines that form the corner.
- Use a corner that is drawn in your layout file.
- Use a true 90° corner. The jigs don't adjust.
- Clean the corner so both faces of the jig sit flat against both walls. Avoid corners with baseboard or trim unless the file reflects it.
- Record corner control points in the same stationing as your other control points. Only the reflector's seat changes: it sits on the jig instead of the control point target.
- Read the error values before you print. A high error on a corner point usually means the corner is out of square, the jig isn't seated flat, or the wall was built off the plan.
Corner control trusts the building as built. Work from an as-built layout file, or tape-check each corner against the drawing before you record it.
Steps and requirements: Use Corner Control Jigs to Station Off Existing Walls.
Wall Stationing (Beta)
Wall Stationing (Beta) stations the laser tracker from scans taken with the reflector held against existing walls, with no control points. It is turned on by request. Contact Dusty Support at support@dustyrobotics.com or (510) 210-3658.
- Scan walls that exist as lines in your layout file.
- Scan at least two walls that are not parallel. Walls close to perpendicular give the best result.
- Hold the reflector flush against the wall for every scan.
- Scan at least three points on each wall and spread them far apart along it.
- Use the blue ring reflector that came with your FieldPrinter. The Dusty App accounts for the 3/4" between its center and the wall, and a different reflector size gives wrong results.
- Check the difference value for each scan before you print. If one scan on a wall is far off from the rest, remove that wall and rescan it.
Wall Stationing (Beta) trusts the walls as built. Work from an as-built layout file, or tape-check the walls you scan against your layout before printing. If your jobsite has surveyed control points, use them.
Steps, requirements, and troubleshooting: Wall Stationing (Beta): How to Station Off Existing Walls.
Related articles
- Understanding Station Information: Reading Distance Errors and Station Errors to Remove Bad Control Points
- How to Select Control Points for Better Stationing Accuracy
- How to Use the Control Point Target to Place the Reflector on a Control Point
- Use Corner Control Jigs to Station Off Existing Walls
- Wall Stationing (Beta): How to Station Off Existing Walls